The following information is for the EMANT300, EMANT380
The Prototype Board Application Adaptor connects the pin out of the DB25 connector of the EMANT300 USB Data Acquisition Module or the EMANT380 Bluetooth Data Acquisition Module to your custom application circuit.
It is used for prototyping of PC Based Data Acquisition Solutions. Together with the EMANT300 USB Data Acquisition Module or the EMANT380 Bluetooth Data Acquisition Module, they allow for connection to real world sensors and signals without the need for fabricating custom printed circuit boards. Soldering is required.
Comprises 2 loose pieces
2-layer printed circuit board with plated through 32 x 25 grid holes
right angled DB25 socket
EMANT300 USB DAQ module male DB25 pin out
EMANT380 Bluetooth DAQ module male DB25 pin out
Note: If you are making any analog input measurements, pin 4 REFIN- must be connected to pin 2 AGND. When you do this the internal reference is correctly set up.
Pin 2 is connected to pin 4 in other application adaptors that measure analog inputs, like the light application adaptor and strain application adaptor. Not all applications require this connection eg when using an external reference or making ratiometric measurements. If you are using the internal reference (default setting), this must be done.
Specification (PDF file size 288K)
Price US$12
Status Discontinued